Definition CVP is generally measured at the junction of the superior vena cava and the right atrium.  This is most commonly this is done via a central venous catheter placed through the right internal jugular vein.  A normal CVP waveform contains five components.  These components include three peaks (a, c, v) and two descents (x, […]