Low Tidal Volumes Parameter Lung-Protective Strategy Traditional Strategy Inflation Volume 5 – 10 mL/kg 10 – 15 mL/kg Mechanical Sighs none 15 – 30 mL/kg at 6 – 12/hr End-Inspiratory Peak Pressure Plateau < 35 cm H2O Peak < 50 cm H2O PEEP 5 – 15 cm H2O Only when needed to keep FiO2 < […]